PT2060/10 PROX Proximity Module
ProvibTech’s PT2060/10 PROX proximity module is a 4 channel proximity signal
conditioner and processing unit. Each channel on the PROX module can accept
any proximity probe system signal input, process it, and output the
processed data. The PT2060/10 PROXmodule can recognize the following
functions:
Shaft Radial Vibration
Axial Thrust Position
Speed
Differential Expansion
Eccentricity
Low Frequency Oscillation
Full
Information In PDF Format (369kBytes)
 |
 |
|
PT2060/20 SEIS Seismic Module
PredicTech’s PT2060/20 AVD seismic module is a 4 channel seismic signal
conditioner and processing unit. Each channel on the AVD module can accept
any proximity probe system signal input, process it, and output the
processed data. PT1060/20 AVD module can recognize the following functions:
Acceleration
Velocity
Displacement
Shaft Absolute Vibration
Case Expansion
Full
Information In PDF Format (289kBytes)
 |
 |
|
PT2060/30 TEMP Temperature Module
ProvibTech’s PT2060/30 TEMP temperature module is an 8 channels temperature
signal conditioner, and processing unit. Each channel on the TEMP module
accept both thermocouple (TC) and resistance temperature detector (RTD)
signal input, process it, and output the processed data.
PT2060/30 back-panel has both isolated and non-isolated version. The
isolated back panel will provide protection to ground loop interference up
to 250VDC. It will accept the TC inputs. The non-isolated version of the
back panel will accept both TC or RTD based on system configuration.
Virtually all the temperature sensors can be interfaced with our PT1060/30
TEMP module. Typical sensors include E, J, K, T thermocouple and 3wire or 4
wire RTDs.
Full
Information In PDF Format (269kBytes)
 |
 |
|
PT2060/40 RELAY Proximity Module
ProvibTech’s PT2060/40 RELAY relay module has 16 channels. Each channel on
the relay module can be fully programmed to perform needed voting logic.
Similar to PLC programming, the PT2060/40 module uses AND and OR logic.
Brackets can also be used. The input parameters include channels: OK, Alert,
and Danger. Programming requires the PT2060CFG configuration software and
the SIM system interface module for communication. The PT2060/40 can be put
into any slot with any number of modules.
Alarm Option
Relay alarm can have the following options:
Latch, non-latching
Normally de-energized, normally energized.
Full
Information In PDF Format (184kBytes)
|
 |
|
PT2060/43 R-RELAY Redundant-Relay Module
ProvibTech’s PT2060/43 R-RELAY redundant-relay module has 16 channels. Each
channel on the relay module can be fully programmed to perform needed voting
logic.
Redundant-Relays
The PT2060/43 module has two separated control circuit. The upper one
controls 8 relays. And the down one controls the rest of the 8 relays.
PT2060/43 can be programmed via. the PT2060-CFG configuration software.
PT2060/43 can only located on slot 4, 8 or 12. Slot 1-4, 5-8, and 912 forms
three group. Each group are triple redundant in channels. The redundant
relay module will perform logic to the channels. The upper 8 relays and the
lower 8 relays perform similar function to realize the redundancy in alarms.
Full
Information In PDF Format (159kBytes)

|
 |
|
PT2060/53 O-SPEED Over-Speed Module
ProvibTech’s PT2060/53 O-SPEED over-speed system provides a highly reliable,
redundant over-speed detection system. PT2060/53 over-speed module can
accept both proximity probe system signal input and magnetic sensor signal
input.
Voting
PT2060/53 over-speed protection system can be configured as a two out of two
or two out of three voting system.
Redundancy Requirement
To reach the maximum system reliability, PT2060/53 requires a redundant
power supply and a redundant PT2060/43 redundant relay module.
Full
Information In PDF Format (233kBytes)
 |
 |
|
PT2060/90 POWER Power Supply Module
ProvibTech’s PT2060/90 POWER power module contains two half height modules.
Customer can use one module or both modules to reach maximum reliability
with redundancy.
PT2060/90 POWER module should be installed on the first slot from the right.
If only one module is used, it should be installed on the top half slot.
PT2060/90 will supply power to all the process modules. The power module can
accept most power supplies in the field, that includes high AC power, high
DC power, low DC power etc.
Full
Information In PDF Format (347kBytes)
 |
 |
|
PT2060/91 SIM System Interface Module
ProvibTech’s PT2060/91 SIM system Interface module is a communication and
system management module.SIM has the following functions:
Communication with up-level control system
Configuration to the rack system and each module
Storage of System Events and Alarm Events
Connection to other racks
Dual phase references.
Full
Information In PDF Format (390kBytes)

|
 |
|
PT2060/96 COMM Communication Phase Reference Module
ProvibTech’s PT2060/96 COMM communication module is a complimentary module.
For the system, if two communications are required, a PT2060/96 should be
added to the system:
Redundant Modbus communication
PT2060/91 has been used with the Modbus connection, additional communication
is required
Ethernet Modbus TCP is required.
Full
Information In PDF Format (274kBytes)
 |
 |
|
PT2060/98 DISP Display Module
ProvibTech’s PT2060/98 DISP display communication module can be connected to
any RS223/RS485 port for displaying the status and system information:
Naming each channel, and arrange the routing
Setup data collection strategy
Put the machine photo and real-time data and status on it
Real-time bar graph / table list / alarm status of each channel
System events / alarm events
Trend plot on each channel
Touch-panel for easy operation.
Full
Information In PDF Format (212kBytes)
 |
 |
|
PT2060/99 Rack System
ProvibTech’s PT2060/99 system rack is a standard 19? monitor that can be
mounted on any standard industrial rack. The rack is a 6U system.
The PT2060/99 contains a total of 16 slots. The two slots on the right hand
side are for system power module and system interface module respectively.
The 3rd and the 4th slots on the right hand side are for the PT2060/80
condition monitoring modules. The signal processing and the relay modules
can take up any of the reset 12 slots. A maximum of 48 channels may be
processed on each rack.
Full
Information In PDF Format (691kBytes)
 |
 |
|
PT2060-CFG System Configuration Software
The PT20560-CFG is the system configuration software. The software requires
a Windows XP or Windows 2000 operating system. The PT2060-CFG has the
following functions:
System configuration
System setup
Rack communication
Modbus option
Module configuration
Trip-multiply
Alarm-inhibit
Module reset
Channel configuration
Measurement type
Alarm set-point
Full